ATTENTION
Never use vegetable oil which will get hard.
9. Press the two start buttons until the hydraulic unit shuts off and the knife is retracted.
10. Fit the pressing ring by turning it clockwise.
11. Tilt the dividing disc downwards.
12. Push the locking pin back in.
13. Fit the front and rear cover.
8.4.
Cleaning under the rounding table
8.4.1.
Required tools
Brush
Damp cloth
Plastic scraper
Compressed air
8.4.2.
Instructions
1. Remove the rounding table by firmly striking it on the underside.
2.
Clean the area under the rounding table with a brush, damp cloth, plastic scraper or compres-
sed air.
3.
Place the rounding table back in position, and make sure the round opening is correctly pres-
sed onto the bearing. Press the rounding table firmly in place.
4. Press the rounding table firmly downwards and check if it is lying flat.
ATTENTION
The rounding table must lie flat.
8.5.
Spare parts
Order spare parts from your dealer or the Daub service department.
Have a qualified service technician install the spare parts. Otherwise, contact your dealer or the
Daub service department.