Connecting the inlet
Use hoses that are suitable for a pressure of at least 1 bar.
Recommended combinations for using the hose sleeves:
Inlet
50 mm (2 in)
38 mm (1½ in)
38 mm (1½ in)
50 mm (2 in)
How to proceed:
 C
1. Push the inlet nozzle into the inlet.
– The inlet nozzle is only necessary for a flow rate < 10000 l/h to ensure unimpaired rotation
of the cleaning rotor.
2. Screw the hose connector with union nut and seal onto the inlet.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the
hose clip.
Connecting the outlet
How to proceed:
 D
1. Screw the adapter with seal onto the outlet and hand tighten.
2. Screw the stepped hose adapter with union nut and seal onto the adapter.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the
hose clip.
4. Screw the cover cap with flat seal onto the outlet.
– The cover cap has to close the outlet opposite the inlet so that the main flow of water is
guided along the UVC lamps and is exposed to the UV radiation for as long as possible.
Connect the unit to the flow-through filter
• Take the required distances into consideration. (→ Distances to be adhered to)
• Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be in-
stalled below the water level. This allows the water supply to be shut off for maintenance
work.
22
Outlet 1
50 mm (2 in)
38 mm (1½ in)
38 mm (1½ in)
38 mm (1½ in)
Outlet 2
(opposite the inlet)
closed
closed
38 mm (1½ in)
38 mm (1½ in)
Required accessories
For outlet 2 , a 38 mm (1½ in)
hose sleeve with a 38 mm (1½ in)
union nut