LP Conversion
Instructions
I- ADJUST
THE LOW FLAME
(SIMMER} SETTING
The top burner valves hove low flame/simmer
adjustment screws accessible through the valve switches.
A flashlight mag be needed to locate the screw. A small,
thin-blade screwdriver (approximatelg 1/8" blade width)
is needed to access the screw.
[]
Light two other burners and set the knobs to
a medium to high setting.
[]
Light the burner to be adjusted and turn the knob
to LOW,
[] To make adjustment, remove the control knobs.
Insert a screwdriver through the access hole in
the valve switch. Engage the adjustment screw
in the valve.
If the flames were too
small or fluttered, open
the valve more than
the original setting.
[]
If the flames ore too Iorge,
close the volve more than
the original setting.
Make the adjustment bg
slowlg turning the screw
until the flame appearance is correct. Forthe left side,
install the grill burner for the adjustment. The left side
cannot be turned down as low as the right side if
the grill burner is to be used.
Adjust the low flame setting using the valve bgpass
screw as follows:
Low setting adjustments must be mode with two
other burners in operation on a medium setting. This
prevents the low flame from being set too low, resulting
in the flame being extinguished when other burners ore
turned on.
[]
Testing Flame Stability:
Test 1:
Test 2:
Test 3:
Turn the knob from HI to LOW quicklg.
If the LOW flame goes out, increase the flame
size and test again.
With the burner on the LOW setting, open
and close the cabinet door under the cooktop.
If the flame is extinguished bg the air currents
created bg the door movement, increase
the flame height and test again.
With the burner on the LOW setting, turn
the downdraft vent fan to the HI position.
If the flame is extinguished bg the air currents
created bg the downdraft vent fan, increase
the flame size and test again.
I- ADJUST
THE LOW FLAME (SIMMER}
SETTING Icont.)
[] Flame Recheck:
Repeat the adjustment for each burner. After
the adjustment is mode, turn oil burners off. Ignite
each burner individuallg. Observe the flame at the HI
position. Rotate the valve to the LOW position and
be sure that the flame size decreases as the valve
is rotated counterclockwise.
161 CONVERTING
BACK TO NATURAL GAS
To convert the cooktop back to natural gas, reverse
the steps token to convert to LR
Natural
Gas 5" W.C.P.
Burner Output Rating in BTU/HR
Location
BTUs
Orifice Size
Engraving
Left Rear (LR)
10,000
.0550
NAT
Left Front (LF)
10,000
.0550
NAT
Right Rear (RR)
10,000
.0550
NAT
Right Front (RF)
10,000
.0550
NAT
Once the conversion is complete and checked OK,
fill out the LP sticker and include your name, organization
and dote conversion was mode. Apply the sticker near
the cooktop gas inlet opening to alert others in the future
that this appliance has been converted to LPgas.
If converting back to natural gas from LP,please
remove the sticker so others know the appliance
is set to use natural gas.
NOTE:For operation at elevations above 5000 ft.
(1500 m), equipment ratings shall be reduced at a rote
of 2% for each 1000 ft. (300 m) above sea level before
selecting appropriately sized equipment, i.e.:Use smaller
orifices.