Power supply cord strain relief
1.
Attach power supply cord
strain relief
Unscrew the removable conduit connector (A) and any
screws from a 19 mm (3/4") strain relief. Put the threaded
section of the strain relief through the hole (B) below the
terminal block opening. Reaching inside the terminal block
opening, screw the removable conduit connector onto the
strain relief threads (C).
2.
Attach power supply cord
to strain relief
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
Go to the "Power Supply Cord Connection" section.
Install Strain Relief
Direct wire strain relief
1.
Attach direct wire strain relief
A
B
C
Unscrew the removable conduit connector (A) and any
screws from a 19 mm (3/4") strain relief. Put the threaded
section of the strain relief through the hole (B) below the
terminal block opening. Reaching inside the terminal block
opening, screw the removable conduit connector onto the
strain relief threads (C).
2.
Attach direct wire cable
to strain relief
Put direct wire cable through the strain relief. The strain relief
should have a tight fit with the dryer cabinet and be in a
horizontal position. Securely tighten strain relief screws.
Go to "Direct Wire Connection."
A
B
C
9