warranty.
• Damage caused by disregard of certain guidelines in this manual is not covered by the warranty
and the dealer will not accept responsibility for any ensuing defects or problems.
• A qualified technician should install and service this device.
• Do not switch the device on immediately after it has been exposed to changes in temperature.
Protect the device against damage by leaving it switched off until it has reached room
temperature.
• This device is designed for professional use on stage, in discos, theatres, etc. The VDPLDJBAR5
should only be used indoors with an alternating current of 230 VAC/50 Hz.
• Lighting effects are not designed for permanent operation: regular operation breaks will prolong
their lives.
• Keep this manual for future reference.
4.
Features
• each light can be oriented separately
• footswitch with 5m cable for easy control
• lighting stand incl., max. height 2m10
• sound controlled or internal program
• with protective carrying case
5.
Overview
Refer to the illustrations on pages 2 and 3 of this manual.
1 light fixture
A connector for LED spot (4x)
B microphone sensitivity control knob
C connector for footswitch
D microphone
E tripod securing knob
F power cord
G fuse holder + fuse
H earth terminal
I mounting points
6.
Mounting instructions
Choosing a Mounting Location
The VDPLDJBAR5 batten has been designed for indoor environments at temperatures up to
40°C. For proper operation, the unit must be operated with an unobstructed air convection
to its metal housing.
Do not:
• Operate the batten in environments with an ambient temperature higher than 40°C and a
relative humidity higher than 75%.
• Operate the batten in a closed environment smaller than 10 m³ unless forced air convection is
provided.
Secure Mounting
Risk of injury. Overhead mounting requires extensive experience: calculating workload
limits, determining the installation material to be used... Have the material and the device
itself checked regularly. Do not attempt to install the device yourself if you lack these
qualifications as improper installation may result in injuries.
• The VDPLDJBAR5 batten is designed to be mounted either on a tripod (incl.) or on a truss (not
incl.) using 2 truss clamps (not incl.).
Tripod:
o Make sure that the diameter of the inserted tripod tube is not less than 25 mm as otherwise
secure mounting cannot be guaranteed.
o Release the legs adjustment knob [3C] and extend the legs to the desired position. Tighten
the legs adjustment knob [3C].
o Place the tripod on a sturdy flat surface capable of carrying at least 10 times the weight of the
VDPLDJBAR5.
o Slide the VDPLDJBAR5 over the tripod and secure it tightly by turning the knob [1E]
clockwise.
o To set the height, release the height adjustment knob [3A] and slide the telescopic pole to the
desired height. Insert the safety pin [3B] into the pole (6 positions possible) and tighten the
27/07/2011
VDPLDJBAR5
2 LED spot
A
horizontal fixing knob
B
vertical fixing knob (2 per spot)
C
LEDs (75 per spot)
3 tripod
A
height adjustment knob
B
safety pin
C
legs adjustment knob
4 2-way footswitch
A
program selection
B
blackout
5
©Velleman nv