VHW200 - VHW201 - VHW210 - VHW211
Technical data
Parameter
Voltage
Power rating
Current
Max vacuum
Maximum air flow rate without hose and
reductions
Maximum air flow rate (3 m Ø 100 mm hose)
Sound pressure level
(Lpf) (EN60335-2-69) (*)
Vibration, ah (**)
Protection
Machine insulation
Motor insulation
Container capacity
Vacuum inlet (diameter)
Allowed hoses
Primary filter surface
Upstream absolute filter surface
Absolute filter efficiency according to MPPS
method (EN 1822)
(*) Measurement uncertainty KpA < 1.5 dB(A). Noise emission values obtained according to EN-60335-2-69
(**) Total value of vibration output to the operator arm and hand
GB
F
D
E
C411
Units of
VHW200
measurement
V
kW
A
mBar
m
/h
3
m
/h
3
dB(A)
m/s
2
IP
Class
Class
L
1
mm
mm
m
0.13
2
m
2
%
8
VHW201
345-415 @50Hz
0.45
1.50
150
72
70
56
≤2.5
55
I
F
6.5
40
40
0.18
1.1
99.995 (H14)