CHARGING A HOT OR COLD BATTERY PACK
If the battery pack in the charging dock is outside of the normal temperature range, the
corresponding battery-bay status indicator will glow solid red and the power indicator
on the battery pack will turn off. When the battery pack cools down or warms up to a
normal temperature range, the battery pack will resume to charge automatically.
BATTERY PACK OR DOCK ERROR
If the battery pack error is detected, the corresponding battery-bay status indicator will
flash red and the power indicator on the battery pack will turn off.
1. Remove and re-insert the battery pack into the dock. If the battery-bay status
indicator still flashes red, try charging a different battery pack that is known to be
functional.
2. If the new replacement battery pack can be charged normally, the original battery
pack is faulty.
3. If the battery-bay status indicator still flashes red after trying to charge a
functional battery pack, reset the hub by unplugging the hub from power supply
and waiting until the hub status indicator goes out. Then reconnect the plug to the
power supply.
4. If the battery-bay status indicator still flashes red after step 3, the dock may be
faulty.
PGX
COMMERCIAL CHARGING 3-PORT DOCK — PGX3000D/PGX3000D-FC
™