Idiomas disponibles

....... 3/8" Lag
..................
Screw
5/8" Washer ,..................
/(not
supplied)
(supplied) i_"
I
Sh,m___rface--
L,ne
Washer
Concrete Anchor
(not supplied)
(not supplied)
6.
Place the (4) 3/8" lag screws
through the air compressor feet,
washers, shims, and into the
anchors.
7.
Torque 3/8" lag screws to
7-10
ft. Ibs.
Wiring instructions
I_1__
Risk of Electrical
Shock. improper
electrical
grounding
can result in
electrical
shock. The wiring should
be done by a qualified
electrician
A qualified electrician needs to knows
the following before wiring:
1.
The amperage rating of the electri-
cal box should be adequate. Refer
to the Specification Chart for this
information.
2.
The supply line should have the
same electrical characteristics
(voltage, cycle, phase) as the
motor. Refer to the motor name-
plate, on side of motor, for this
information.
NOTE: The wiring must be the same
as the motor nameplate voltage plus
or minus 10%. Refer to local codes for
recommended
wire sizes, correct wire
size, and maximum wire run; undersize
wire causes high amp draw and over-
heating to the motor.
I__
Risk of Electrical
Shock. Electrical
wiring must be located away from
hot surfaces
such as manifold
assembly,
compressor
outlet tubes,
heads, or cylinders.
GROUNDING
iNSTRUCTiONS
This product should be connected
to
a metallic, permanent wiring system,
of an equipment-grounding
terminal
or lead on the product.
Voltage and Circuit Protection
Refer to the specification
chart for the
voltage and minimum branch circuit
requirements.
Air Distribution System
E__
isk of Bursting.
Plastic or PVC
pipe is not designed
for use with
compressed
air. Regardless of its
indicated pressure rating, plastic
pipe can burst from air pressure.
Use only metal pipe for air
distribution
lines.
The next figure represents a typical
air distribution system. The following
are tips to remember when setting up
the air compressor's air distribution
system.
+
Use pipe that is the same size as
the air tank outlet. Piping that is
too small will restrict the flow of
air.
+
If piping is over 100 feet (30.5 m)
long, use the next larger size.
+
Bury underground
lines below
the frost line and avoid pockets
where condensation
can gather
and freeze. Apply pressure before
underground
lines are covered to
make sure all pipe joints are free
of leaks.
+
A flexible coupling is recommend-
ed to be installed between the air
discharge outlet and main air dis-
tribution line to allow for vibration.
+
A separate regulator is recom-
mended to control the air pres-
sure. Air pressure from the tank
is usually to high for individual air
driven tools.
11-ENG