CODE
POSSIBLE CAUSE
POSSIBLE SOLUTION
24
Fuse blown, circuit breaker tripped
1. Check
fuse
box
for
blown
fuse
and
replace
as
necessary. Reset circuit breaker. Do not use a fuse or
circuit
breaker with higher rating than that specified
for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check
for
low voltage
conditions
and/or
proper
extension
cord.
4. Disconnect
the other electrical appliances
from circuit
or operate the compressor
on its own branch circuit.
25
Tank pressure exceeds pressure Switch Cut:in pressure
Motor Will Start aut0matically
when tan k preSsUre d tops
i
below cut-in pressure of pressure switch:
26
Pressure release valve on pressure switch has not
Set the On/Off switch to OFF. If the valve does not open,
unloaded head pressure
replace switch. Contact a DEWALT factory service center
or a DEWALT authorized
service center.
24