Descargar Imprimir esta página

RIDGID OF60150HB Manual Del Operador página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
WARNING:
Always release all pressure, disconnect from power
supply, and allow unit to cool to the touch before
cleaning or making repairs on the air compressor.
WARNING:
Always wear eye protection with side shields
marked to comply with ANSI Z87.1. Failure to do
so could result in objects being thrown into your
eyes resulting in possible serious injury.
WARNING:
When servicing use only identical replacement
parts. Use of any other parts may create a hazard
or cause product damage.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline,
petroleum-based products, penetrating oils, etc.,
come in contact with plastic parts. Chemicals can
damage, weaken or destroy plastIc which may
result in serious personal injury.
NOTE: ILLUSTRATIONS START ON PAGE 16 AFTER
This product has a 90-Day Satisfaction Guarantee Policy, as well
as a Three-year Limited Warranty. For Warranty and Policy details,
please go to www.RIDGID.com or call (toll free) 1-866-539-1710.
FRENCH AND SPANISH LANGUAGE SECTIONS.
REPLACING GAUGES, QUICK CONNECT
COUPLERS, OR SAFETY VALVE
See Figure 7, page 17.
 Remove two screws securing the console cover. Remove
cover and set aside.
 Using an adjustable wrench, remove the item(s) to be
replaced (gauges, quick connect couplers, and/or safety
valve) from the regulator manifold.
 Apply pipe sealant to new part(s) and then install new
parts on manifold. Tighten securely.
NOTE: If replacing gauges, make sure to orient new
gauges correctly for reading.
 Reinstall console cover and replace screws. Tighten
securely.
13 – English

Publicidad

loading