GLOSSARY OF TERMS
Air Tank
Cylindrical component which contains the compressed air.
Check Valve
Device that prevents compressed air from flowing back from
the air tank to the compressor pump.
Cut-In Pressure
The low pressure at which the motor will automatically restart.
Cut-Out Pressure
The high pressure at which the motor will automatically
shut off.
Electric Motor
Device which provides the rotational force necessary to
operate the compressor pump.
NPT (National Pipe Thread)
A seal thread tape must be used to provide a leak-free seal
on pipe threaded connections.
On/Off Switch
Control which turns the air compressor on or off. The pressure
switch will not automatically start and control the compressor
unless the manual On/Off Switch is in the ON ( l ) position.
Overload Switch (Internal)
Automatically shuts off the compressor if the temperature of
the electric motor exceeds a predetermined limit.
Pressure Regulator Knob
Regulates the outgoing pressure from the air outlet to the
tool. It is possible to increase or decrease the pressure at
the outlet by adjusting this control knob.
FEATURES
PRODUCT SPECIFICATIONS
Air Tank Capacity ........................................................................................................................................................... 6 gal.
Air Pressure .........................................................................................................................................................150 psi max.
Air Delivery ............................................................................................................................................... 2.6 SCFM @ 90 psi
Gauges ........................................................................................................................................................... 1.5 in. diameter
Input .................................................................................................................................. 120 V, AC only, 60 Hz, 10.4 Amps
Pressure Switch
Automatically controls the on/off cycling of the compressor. It
stops the compressor when the cut-out pressure in the tank
is reached and starts the compressor when the air pressure
drops below the cut-in pressure.
PSI (Pounds Per Square Inch)
Measurement of the pressure exerted by the force of the
air. The actual psi is measured by a pressure gauge on the
compressor.
Pump
Produces the compressed air with a reciprocating piston
contained within the cylinder.
Regulator Pressure Gauge
Displays the current line pressure. Line pressure is adjusted
by rotating the pressure regulator knob.
Safety Valve
Prevents air pressure in the air tank from rising over a
predetermined limit.
SCFM (Standard Cubic Feet Per Minute) or CFM (Cubic
Feet Per Minute)
A unit of measure of air delivery.
Tank Pressure Gauge
Indicates the pressure in the air tank.