Current Draw Table (in Amperes)
Table 3
provides typical current draw for each model as a function of load and output power level. Units of measurement are Amperes r.m.s.
NOTE: Current draw shown is for 120 VAC line. For 230 VAC models, multiply values shown by 0.5 .
• 1/8 power (pink noise) represents typical program with occasional clipping. Use this rating for most applications.
• 1/3 power (pink noise) represents severe program with heavy clipping.
• Full power (sine) is continuous sine wave driven at 1% clipping.
• Thermal or overcurrent cutback limits duration of full power 2 Ohm operation.
Model
CX204V
CX254
CX302
CX302V
CX404
CX502
CX602V
CX702
CX902
CX1102
CX1202V
1/8 Power
Load
Idle
(pink noise)
70V (x4)
0.8
8 (x2)
0.7
4 (x2)
0.7
2 (x2)
0.7
14.3
8 (x2)
0.8
4 (x2)
0.8
2 (x2)
0.8
70V (x2)
0.8
8 (x2)
0.7
4 (x2)
0.7
12.4
8 (x2)
0.9
4 (x2)
0.9
2 (x2)
0.9
14.0
70V (x2)
0.9
8 (x2)
0.9
4 (x2)
0.9
2 (x2)
0.9
11.8
8 (x2)
0.9
4 (x2)
0.9
2 (x2)
0.9
14.0
8 (x2)
0.9
4 (x2)
0.9
11.6
2 (x2)
0.9
16.6
70V (x2)
0.9
12.0
— Table 3 —
13
1/3 Power
Full Power
(pink noise)
(sine)
7.7
12.1
14.0
5.8
8.8
14.8
9.2
14.2
24.0
24.0
38.0
3.8
5.4
8.4
6.0
8.9
14.0
9.6
14.3
23.0
5.7
8.0
16.0
8.1
12.2
22.0
19.3
38.0
5.6
8.0
12.5
9.0
13.3
21.0
21.0
34.0
8.7
13.0
21.0
5.0
8.4
15.8
7.9
13.5
26.0
22.0
42.0
6.0
11.0
20.0
9.5
17.0
33.0
27.0
50.0
7.6
13.1
25.0
20.0
39.0
19.0
39.0
EN
TD-000077-00-K