Kenmore 110.81422 Manual De Uso Y Cuidado E Instrucciones De Instalación página 6

Centro de lavanderïa de 24' (61 cm) de ancho lavadora - secadora eléctrica

Publicidad

Idiomas disponibles

Idiomas disponibles

ALTERNATE
PARTS
Parts listed are available
from your local
Sears store or
Sears Service
Center.
For further
information,
please
call
1=800=4=MY-HOME
® (1=800=469=4663).
If you
have:
Laundry
tub or
standpipe
taller
than
96" (2.4 m)
1" (25 mm)
diameter
standpipe
Overhead
sewer
Floor drain
You will
need
to buy:
Sump pump
system (if not already
available)
2" (51 mm) diameter
to 1" (25 mm)
diameter
standpipe
adapter,
Part Number
3363920
Standard
20 gal. (76 L) 34" (864
mm)
tall drain
tub or utility
sink and sump
pump
(available
from local
plumbing
suppliers)
Siphon
break,
Part Number
285320,
additional
drain
hose, Part Number
285702,
and connector
kit, Part
Number
285442
Drain hose too short
Lint clogged
drain
Water
faucets
beyond
reach
of fill hoses
Drain hose, Part Number
285664
and connector
kit, Part Number
285442
Drain protector,
Part Number
367031
2 longer
water
fill hoses:
6 ft (1.8 m), Part Number
76314,
10 ft (3.0 m), Part Number
350008
LOCATION REQUIREMENTS
Explosion Hazard
Keep flammable
materials
and vapors, such as
gasoline, away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion, or fire.
You wlll
need
[]
A location
that allows
for proper
exhaust
installation.
See
"Venting
Requirements".
[]
For 240 volt models,
a separate
30-amp
circuit.
For 120 volt
models,
a 120 volt, 60 Hz., AC only, 15- or 20-amp
circuit.
[]
If using a power
supply
cord on 240 volt models,
and for 120
volt models,
a grounded
electrical
outlet
located
within
2 ft.
(610 ram) of either
side of the Laundry
Center. See "Electrical
Requirements".
[]
A sturdy floor
to support
the Laundry
Center
weight
(Laundry
Center, water, and load) of 500 Ibs (226.8
kg).
[]
A level floor
with a maximum
slope of 1" (25 mm) under
entire
Laundry
Center. Clothes
may not tumble
properly
and
automatic
sensor cycles
may not operate
correctly
if Laundry
Center
is not level. Installing
on carpet
is not recommended.
[]
A water
heater
set to deliver
120°F (49°C)
water
to the washer.
[]
Hot and cold water
faucets
located
within 4 ft (1.2 m) of the
hot and cold water
fill valves, and water
pressure of 5-100
psi
(34.5-689.6
kPa).
The Laundry
Center
must not be installed
or stored
in an area
where it will be exposed
to water
and/or
weather.
6
Do not operate
your washer
in temperatures
at or below
32°F
(0°C). Some water
can remain
in the washer
and can cause
damage
in low temperatures.
See "Vacation,
Storage,
and Moving
Care" for winterizing
information.
Do not operate
your dryer
at temperatures
below
45°F (7°C).
At
lower temperatures,
the dryer
might not shut off at the end of an
automatic
cycle. This can result in longer
drying
times.
Check code requirements.
Some codes limit, or do not permit,
installation
of the Laundry
Center in garages,
closets, mobile
homes, or sleeping
quarters.
Contact
your local
building
inspector.
Installation Clearances
The location
must be large
enough
to allow
the dryer door
to open
fully.
Laundry
Center
Dimensions
15 3/o"
(390 ram)
71%"
(1.82 m)
(816 ram)
*27 ¼"
"_
(692 ram)
*23 z/8"
(606 ram)
*Most installations
require a minimum
5" (127 ram) clearance
behind
the dryer for the exhaust vent with elbow. See "Venting Requirements".
Minimum spacing far recessed area or closet installation
The following
spacing
dimensions
are recommended
for this
Laundry
Center. This Laundry
Center
has been tested for spacing
of 0" (0 mm) clearance
on the sides, rear, and top. Recommended
spacing
should
be considered
for the following
reasons:
[]
Additional
spacing
should
be considered
for ease of installation
and servicing.
[]
Additional
clearances
might be required
for wall, door, and
floor
moldings.
[]
Additional
spacing
on all sides of the Laundry
Center is
recommended
to reduce
noise transfer.
[]
For closet installation,
with a door, minimum
ventilation
openings
in the top and bottom
of the door are required.
Louvered doors
with equivalent
ventilation
openings
are acceptable.
o oo
o o
m
1"--_1N-26'/_"-_11_-_"
(25 mm) (606 r am) (25 rnm)
A
_I"* 1-27'J,"÷I
(25 mm) (692 m m)
B
A. Recessed area
T (305 turn},
__
3!'(76 m m)
48 in, ; < .-1
(310crn
2) I_
t
(155cm2} I
'(76ram)
_.- 6"**
(127 m m)
C
B. Side view - closet or confined
area
C. Closet door with vents
*Required
spacing
**Rear
clearance
may be 0" (0 mm) when house exhaust system
is lined up directly
with dryer exhaust.