9
Remote Gassing Connection
If the gas detector is installed in an inaccessible location, such as overhead on a ceiling, connect a tube to the gas
detector for bump test.
10 Status Indicator
The detector features an external visual status indicator on its front face.
Normal: The indicator is lit GREEN when the concentration of the target gas is within normal range.
The Normal indication can also be set to Confidence Flash or Off.
Alarm: RED flashes rapidly when the gas concentration is beyond the alarm-level threshold.
Fault: YELLOW flashes rapidly when the gas detector is in a fault state.
Bluetooth pairing: BLUE flashes when Bluetooth® pairing between the gas detector and a
smartphone is in progress.
Bluetooth connected: Steady BLUE is lit when a Bluetooth connection is established.
11 Connecting to a Detector via Bluetooth (Bluetooth versions only)
To pair your smartphone with a specific detector, follow these steps:
1. Download Sensepoint App from Google Play Store. Install and launch the app.
2. Create and register a user account, and log on with the created account information.
3. To associate with one or more gas detectors, scan the QR code on the sheet included in the box or enter its
Activation Key.
4. Complete the installation of the detectors.
5. On the app's home screen, tap DETECTORS to scan for available detectors.
6. Select a detector from the detector list to pair with it.
7. Look for the detector whose Status Indicator is flashing blue.
8. Tap Confirm Detector to pair with that detector. Otherwise, tap Return to list to select one of the others.
2. Position the detector module onto the back box ensuring that the Status Indicator is in
the top left-hand corner when viewed from the front.
3. Tighten the four retaining screws using a No. 2 Phillips screwdriver to secure.
4. Where used, tighten the sealing nut of the cable gland to secure the cable. Refer to the
cable gland manufacturer's instructions.
5. Replace the front cover by placing it into the detector module and rotate it clockwise
until it locks into position.
•
For a temporary connection, open the flap on the bottom side and
connect suitable tubing compatible with the gas type of the sensor to
the tube spigot.
•
For a permanent connection, remove the flap, connect the tube
connector (available separately) to the spigot, and then connect a tube
to the tube connector. Secure the tube using a cable tie or small jubilee
clip, taking care not to over-tighten it.
3
3