Descargar Imprimir esta página

GE 18 Manual Del Propietario E Instalación página 33

Refrigeradores congelador superior
Ocultar thumbs Ver también para 18:

Publicidad

Idiomas disponibles

Idiomas disponibles

Performance Data Sheet
SmartWater FiltrationSystem
GSWFCartridge
Thissystemhas been tested accordingto NSF/ANS142/53for reductionof the substanceslisted below.
Theconcentrationof the indicatedsubstancesin water entering the systemwas reducedto a concentration
less than or equal to the permissible limit for water leaving the system,as specified in NSF/ANS142/53.*
(100%safety factors built in for unmetered usage)
Pm'ameter
USEPA
MCL
Chlorine
T&O
Par ticulatc**
hlfluent
Average
1.845
mg/L
143,333
#/mL
Standard No. 42: Aesthetic Effects
Influent
C_dlenge
Effluent
Concentration
Average
Maximum
2.0 mg/L+ 10%
< 0.05 mg/L
0.05 mg/L
at least10,000parfides/mL
29.83 #/mL
140 #/mL
% Reduction
Average
Mhthnmn
> 97.29%
96.43%
99.98%
99.91%
Min. Required
Reduction
>50%
>85%
Pl_dealneter
'lhrhidi W
Lead at pH 6.5
Lead at pH 8.5
Lindane
AtraTJne
USEPA
MCL
1 N'III***
99.95%
Reduction
0.015
mg/L
0.015
mg/L
0.0002 mg/L
0.0113 ing/L
Influent
Average
10.3 ]"rll.J***
200,000
#/L
0.15 mg/L
0.14 mg/L
0.0216
mg/L
0.008
mg/L
Standard No.
hlfluent Challenge
ConcenWafion
1+1 NTU***
Minimum 50,000 L
0.15 rag/L+ I0%
0.15 mg/L+10%
0.002 mg/L+10%
0.009 mg/L+10%
53: Health
Effects
Effluent
Average
Maximum
0.106
NTU
0.14 NTU
0
0
< 0.001
mg/L
< 0.001
mg/L
0.001
mg/L
0.003
mg/L
: 0.00002
mg/L
< 0.00(_)2 mg/L
< 0.002
mg/L
< 0.002
mg/L
% Reduction
Average
Minimum
98.97%
98.61%
> 99.99%
> 99.99%
> 99.33%
> 99.33%
> 99.29%
97.86%
99.07%
98.75%
> %.12%
> ('_i.67%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002
mg/L
0.003 mg/L
* Testedusing a flew rate of 0.5 gpm;pressureof 60 psig' pHof Z 5 J:0.5; temp.of 68°+-5°I=(20° +-3°C)
** Measurementin Particles/mLParticlesusedwere0.5-1microns
*** NTU=Nephelometric T urbidity units
Operating Specifications
• Capacity: certified tbr up to 750 gallons (2,838 1); up to six months
• Pressure
requirement:
40-120 psi (2.8-8.2 bar)
• Temperature:
33-100°F
(0.6-38°C)
• Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance
Requirements
• Flush
new cartridge
at tull flow for 3 minutes
to purge
out trapped
air.
• Replace
cartridge
when
1low becomes
too slow.
Special Notices
• Installation
instructions,
parts
and smwice
availability,
and
standard
warranty
are included
with the product
when
shipped.
• This drinking
water
system
must
be maintained
according
to manuthcturer's
instructions,
including
replacement
of filter
cartridges.
• Do not use with water that
is microbiologically
unsate
or of unknown
quality
without
adequate
disinfection
betore
or
after the system.
Systems
certified
for cyst reduction
may be used on disinfected
u-ater that may contain
filterable
cysts.
• The
contaminants
or other
substances
removed
or reduced
by this water
treatment
system
are not necessarily
in your
water.
• Check
for compliance
with the state and local
la,a_ and regulations.
• Note
that while the testing
was performed
under
standard
laboratory
conditions,
actual
pertormance
may vary. Systems
must
be installed
and
operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
I
stem
tested
and
certified
by NSF lnlernational
against
Slandard
42 for the reduction
of
chlorine,
laste
and
odor,
parliculate
Class
i mad Standard
53 tor the
reduction
of cyst,
lead,
Lindane,
AtraTine
and
turhidity.
Manufactured
tor:
General
Electric
Company,
Louisville,
KY 40225
33

Publicidad

loading

Este manual también es adecuado para:

19