LAYOUT AND DESIGN
Maximize your flow by using less fittings in your design - Pre planning your
layout before you begin installation will help you install the system faster and
using just the right amount of fittings. To maximize your air flow we would
recommend a looped piping layout, this may not be necessary or convenient
in what you are planning. Create a plan as to the location of the air compressor
and where you are going to mount the compressed air outlets. On the plan
consider what fittings you will use where or where you plan to bend the line to
keep the continuous flow. Do not install underground, or in concrete.
NOTE: If installing outside we recommend covering or painting the tubing with
water-based latex paint to protect from the harmful UV rays.
AIR COMPRESSOR
DO NOT setup this kit directly to your compressor. You will need to purchase a
¾" NPT Hydraulic Hose (IA165-0331RP) to connect your compressor to the filter
regulator unit to reduce vibration to the tubing.
FILTER REGULATOR
A high quality ¾" Filter regulator filter is recommended to catch oils entering the
air system. A filter regulator must be used.
RATINGS
200 psi at 73°F 160 psi at 140°F ASTM F1281
BENDING THE TUBING
The tubing can be bent to hold any shape. Care should be taken not to kink
the tubing, but rather bend the tubing in a sweeping radius no less than 6"-8"
around corners and obstacles. Elbow fittings are available for sharp corners.
THREADED COMPONENTS ASSEMBLY
Gather all threaded components and apply two wraps of PTFE Tape on the
threads. To prevent galling you may also apply a pipe sealant.
TUBING AND WALL BRACKET INSTALLATION
Tubing will expand and contract slightly with changes in temperature. Use wall
clips spaced 5 ft for 3/4" tubing.
CHECKING INSTALLATION
After tubing is installed be sure to check for air leaks. Pressurize system with air,
and spray soapy water solution onto each connection. No foam or bubbles from
solution should be present.