x2
0---
10--
ALT
follow the user guide
add. start
hidden butt
Add. 2ch
hidden butt
erase 64
language
autoset
Control unit
software version
stat
OK
vers
bft . . .
+/-
No total
- +
manoeuvres(in hundreds)
OK
0000
n. cycles
+/-
- +
No radio control
devices memorised
n. remotes
OK
00
+/-
- +
List of last 30 errors
01.33
OK
err
02.01
........
30.15
+/-
0---
password
www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com
ACCESS MENUS Fig. 2
150-
1520
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
See RADIO MENU
Diagnostics
DESCRIPTION
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
BAR safety edge input activated on slave motor
BAR 2
(opposite leaves connection)
Activation of BAR safety edge input with ACTIVE reversal
ONLY WHILE OPENING, or, if configured as verified safety
baro
edge active only while opening, Activation of the asso-
ciated FAULT input
Activation of BAR safety edge input with ACTIVE rever-
sal ONLY WHILE CLOSING, or, if configured as verified
barc
safety edge active only while closing, Activation of the
associated FAULT input
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
Safety edge test on slave motor failed (opposite leaves
ER05
connection)
8k2 safety edge test failed
er06
Opening safety edge test failed
ER07
Closing safety edge test failed
ER08
Board hardware test error
ER1x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters (Logics
ER72
and Parameters)
D-track parameter error
ER73
Limit switch error
ERf0
Limit switch error always active after operation start
erf1
Error in setting the SAFE inputs
ERf3
* X = 0,1,...,9,A,B,C,D,E,F
10--
150-
ok
Request with Protection Level logic set to 1, 2, 3, 4
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical assistance)
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory devices
and/or expansion boards
Try switching the board off and back on again. If the problem
persists, contact the technical assistance department.
Pressing OK the detected settings are confirmed. The board will
keep on working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track as
a default.
An autoset is required
check limit switch connections
Check limit switch and motor connections
Check the setting of the SAFE inputs is correct
1520
prg
*** Password entry.
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
ARES ULTRA BT A 1500 - 1500 V
UL
19
-