Descargar Imprimir esta página

ABL Wallbox eM4 Single Instrucciones De Uso página 28

Ocultar thumbs Ver también para Wallbox eM4 Single:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
Taking the Wallbox eM4 Single out of operation
In case of severe malfunctions or damage to the device, you must take the Wallbox eM4 Single out of operation. To
do so, proceed as follows:
1 Unlock the wallbox's side RCCB flap using the key
supplied and flip it up.
2 Flip the toggle switch of the RCCB to the
0 position.
3 Close the RCCB flap and lock it with the key.
4 Open your domestic power distribution box,
disconnect the wallbox's power supply cable from
the electricity grid via the MCB, secure the MCB
against being switched on again and close the
distribution box.
The Wallbox eM4 Single is no longer connected to the electricity grid and can be removed by a qualified specialist
electrical contractor if required.
28
Taking the Wallbox eM4 Single out of operation
1
1
+
0
0
1
0

Publicidad

loading

Productos relacionados para ABL Wallbox eM4 Single