Note: The thermostat does not allow the maximum temperature to be set
lower than the maximum temperature, or lower than the temperature set
for Protection against overheating (see 2.6). This setting also serves as a
limit to protect against floor overheating (which is measured via the Floor
Probe), so that the floor temperature does not go exceed the maximum
temperature limits set.
2.5 Calibration (adjust temperature read by the thermostat to real temperature)
Press
to navigate between options (Ambient Sensor or Floor Probe). Press
OK to confirm or
2.5.1 Ambient Sensor
Press
+3,0 °C). Press OK to confirm and exit. (Default setting: 0,0 °C).
2.5.2 Floor Probe
Press
+3,0 °C). Press OK to confirm and exit (Default setting: 0,0 °C).
2.6 Antifreeze/Overheating Protection setting
2.6.1 Antifreeze Protection (antifreeze protection temperature can only be
set when in heating mode)
Press
(5,0 °C to -0,5 °C). Press OK to confirm and exit. (Default setting:
8,0 °C). If the selected installation type is hydraulic (see 2.2), the
Antifreeze temperature must be above 16 °C in order to reduce the
probability of condensation forming in the pipes.
to go back.
or
to select the desired calibration (between -3,0 °C and
or
to select the desired calibration (between -3,0 °C and
or
to select desired Antifreeze Protection Temperature
39