Ambient Sensor Monitoring - The temperature is monitored via the
equipment's ambient temperature sensor.
Note: When this monitoring mode is active, . will appear on the display.
In this operating mode, the Ambient Sensor will also perform Antifreeze/
Overheating Protection (see 2.6).
Floor Probe Monitoring - Temperature is monitored by the Floor Probe.
Note: When this monitoring mode is active,
In this operating mode, in addition to monitoring the temperature, the
Probe will also perform Antifreeze/Overheating Protection (see 2.6),
preventing the floor from exceeding the defined maximum/minimum
temperatures set, thus avoiding overheating/overcooling of the floor.
Ambient Sensor Monitor + Floor Probe - The temperature is monitored
via the equipment's ambient temperature sensor and the Floor Probe,
preventing overheating/overcooling of the floor by preventing the floor
temperature from exceeding the maximum/minimum temperature
limits set.
Note: When this monitoring mode is active,
In this mode, the temperature will be monitored by the Ambient Sensor
and the Probe will perform Antifreeze/Overheating Protection (see 2.6),
preventing the floor temperature from exceeding the defined maximum/
minimum temperature limits, thus avoiding overheating/overcooling of
the floor.
. will appear on the display.
will appear on the display.
41