Descargar Imprimir esta página

Contest VERSATILE COLOR VH20-90 Manual Del Usuario página 19

Proyector arquitectonico con efecto de agua en color ip66 90 w led - 7800 k - 25,40 y 55

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

VH2O-90 - IP66 color water effect architectural projector
6.3 - Outdoor line wiring with junction box and VC-YHYB adapter :
For outdoor connections that must remain sealed, you can use a junction box and a hybrid Y adapter to distribute the power and the DMX as
shown in the figure below.
Power
16A (3500W maxi)
N
L
GND
D-
D+
DMX
1x boîte IpBox-p4
2x câblesVC-End1/3
1x FastCon-1333POW
1x FastCon-1333DMX
6.4 - Projector chains :
The wiring of a projector group can be done in different ways. The hybrid cables are used to supply the projector with electricity and data. The
chaining of the projectors can be done simply as shown in the figure below.
Hybrid connection cords
between the projectors
VC-JUMP are available
from 1m to 10m length
6.5 - Line lenght :
The number of projectors on a single line depends on the length of the wiring, its section (here 3 x 1.5 mm2) and the type of projector
associated, as shown in the table below. A safety margin is applied to guarantee the correct operation of the installation.
A line is the length from the feed point to the last fixture.
PROJECTOR
VCOB-60DW
VCOB-120DW
VBAR-50DW
VBAR-100DW
VPAR-70DW
VPAR-120DW
VPAR-150DW
VCOB-60RGBL
VCOB-150RGBL
VBAR-50RGBL
VBAR-100RGBL
VPAR-70RGBL
VPAR-120RGBL
VPAR-150RGBL
VPANEL-200RGBL
VH2O-90
Avaible power on each line
architectural-lighting.eu
IN
OUT
architectural-lighting.eu
IN
OUT
VC-YHYB
architectural-lighting.eu
IN
OUT
Qty on 10 m
31
14
32
19
27
16
11
31
12
32
19
27
16
11
9
22
2300 W
architectural-lighting.eu
IN
architectural-lighting.eu
IN
architectural-lighting.eu
IN
architectural-lighting.eu
IN
OUT
Qty on 20 m
Qty on 30 m
30
20
14
10
32
23
19
12
26
17
16
10
11
30
20
12
32
23
19
12
26
17
16
10
11
9
21
13
2216 W
1477 W
OUT
OUT
architectural-lighting.eu
IN
Qty on 50 m
11
6
13
7
10
6
8
5
11
8
5
13
7
10
6
8
5
6
3
7
886 W
English
CAUTION !
The sum of the pow-
ers of the different
lines must not
exceed the power
of the Power input
(3500W)
OUT
Qty on 100 m
5
2
6
3
4
2
2
5
2
6
3
4
2
2
1
3
443 W
Page 19

Publicidad

loading