PROBLEM
CORRECTION
6.
No or low
pressure
(initial use)
(continued)
Will not draw
chemicals
6.
CAUSE
Air in hose.
7.
Choke lever in the
"Choke" position.
8.
Throttle control lever is
not in the "Fast" position.
9.
High pressure hose is too
long.
1.
Wand not in low
pressure.
2.
Chemical filter clogged.
3.
Chemical screen not in
chemical
4.
Chemical too thick
5.
Pressure hose is too long
Chemical build up in
chemical injector.
7.
8.
9.
Turn off the engine, then the
water source. Disconnect
the water source from the
pump inlet and turn the
water source on to remove
all air from the hose. When
there is a steady stream of
water present, turn water
source off. Reconnect water
source to pump inlet and
turn on water source.
Squeeze trigger to remove
remaining air.
Move choke to the "No
Choke" position.
Move throttle control lever to
the "Fast" position.
Use high pressure hose
under 100 feet.
1.
See Spray Wand paragraph
in the Maintenance section
for the correct procedure.
2.
Clean filter.
3.
Insure end of chemical hose
is fully submerged into
chemical.
4.
Dilute chemical. Chemical
should be the same
consistency as water.
5.
Lengthen water supply hose
instead of high pressure
hose.
6.
Have parts cleaned or
replaced by AWSC.
19- ENG
A04549