19
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 0.1s, Maximum 25s, Default off
20
Final current
Makes it possible to regulate the current delivered in
the burn back phase.
Allows the more or less "violent" burning of the wire.
Minimum 12A, Maximum Imax, Default syn
36
Stickout calibration
Makes it possible to perform a generator calibration
depending on the operating conditions of the system.
Allows precise correspondence to be obtained between
the values of the parameters set and the values read
(consult the "Stickout calibration" section).
37
Guard limits
Allows the setting of the warning limits and of the guard
limits.
Allows the accurate control of the various welding
phases (consult the "Guard limits" section).
38
Starting filter
Allows the control of the guard limits to be enabled with
an adjustable delay in relation to the arc striking.
Makes it possible to filter the striking phase (consult the
"Guard limits" section).
39
Output filter
Makes it possible to disenable the control of the guard
limits in advance of the natural closing of the weld.
Makes it possible to filter the extinction phase (consult
the "Guard limits" section).
40
Current reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the "Interface personalisation" section).
41
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the "Interface personalisation" section).
42
Gas flow reading
Allows the real gas flow value to be displayed.
Allows the setting of the gas flow display method (con-
sult the "Interface personalisation" section).
43
Robot movement speed
Allows the arm movement speed of a robot or an auto-
mation device to be displayed.
44
Regulation step
Allows the regulation of a parameter with a step that can
be personalised by the operator.
Minimum 1, Maximum Imax, Default 1
45
External parameter 1
Allows the management of external parameter 1 (mini-
mum value, maximum value, default value, parameter
selected).
(Consult the "External controls management" section).
46
External parameter 2
Allows the management of external parameter 2 (mini-
mum value, maximum value, default value, parameter
selected).
(Consult the "External controls management" section).
47
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
38
48
Buzzer tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
49
Contrast
Permits adjustment of the display contrast.
Minimum 0, Maximum 50, Default 25
List of set up parameters (Pulsed MIG/MAG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Synergy
Allows selection of the manual MIG
(
) or synergic MIG (
the type of material to be welded.
(Consult the "Synergic curves screen" section).
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 1 m/min, Maximum 22 m/min, Default
1.0m/min
4
Current
Allows the regulation of the welding current.
Minimum 6A, Maximum Imax
5
Part thickness
Allows the thickness of the part being welded to be set.
Allows the setting of the system via the regulation of the
part being welded.
6
Voltage
Allows the regulation of the arc voltage.
Allows regulation of the arc length during welding.
High voltage = long arc
Low voltage = short arc
Minimum -9.9V, Maximum +9.9V, Default syn
7
Peak current
Allows the regulation of the impulse current.
Makes it possible to increase or reduce the size of the
droplets of molten material coming off the wire.
Minimum -50A, Maximum +50A, Default syn
8
Basic current
Allows the regulation of the maintenance current. Makes
it possible to increase or reduce the heat in the molten
pool and the energy of the electric arc.
Minimum -50A, Maximum +50A, Default syn
9
Frequency
Allows the regulation of the impulse frequency.
Makes it possible to increase or reduce the number of
droplets of molten material coming off the wire and to
change their consistency.
Minimum -50Hz, Maximum +50Hz, Default syn
10
Double pulsed
Allows enablement of the "Double Pulsed" function.
Allows regulation of the pulsation amplitude.
Minimum 0%, Maximum 100%, Default off
11
Pulsation time
Allows regulation of the cycle, i.e. of the impulse rep-
etition cycle.
Allows the impulse frequency to be regulated.
Minimum 0.1s, Maximum 10.0s, Default 0.5s
) process by setting