08. Instalation
INCORRECT INSTALLATION OF THE MACHINE MAY CAUSE DAMAGE
TO PEOPLE, ANIMALS OR OBJECTS. THE MANUFACTURER CANNOT BE
CONSIDERED RESPONSIBLE FOR THESE DAMAGES
08.1. Transport and discharge
The remover is delivered packaged. It must be transported and stored according to the indications
on the packaging. Due to the low weight of the remover can be moved by two people without using
other means.
08.2. Arrangement of the lighting system
The Client must make sure that there is suitable lighting for the surroundings and that the lighting
conforms to the regulations in force. In particular, the Client must arrange the positioning of lighting
that illuminates all the working area.
08.3. Arrangement of the pneumatic system
The Client must arrange a line of filtered compressed air supplied by a compressor that is suitable
for the consumption required.
Do not use compressed air that contains chemical products, synthetic oil with organic solvents, salts
or corrosive gases as they can cause damage or malfunctioning.
The line of compressed air must arrive up to the supply points of the machine. If the compressed air
contains a large amount of moisture, it may cause malfunctioning in the valves and in the pneumatic
components. Install a moisture separator downstream from the compressor to avoid this.
08.4. Classification according to the ATEX directive
The machine conforms to the essential requisites of the EU Directive 2014/34/UE, better known
as ATEX ("Explosive atmospheres"). It is classified as group II category 3 letter G system. The
assessment procedures of conformity, carried out by an internal factory check, allow the installation
of the machine in surroundings where there may be potentially explosive atmospheres due to the
presence of gas, fumes or mist.
08.5. Equipment assembly
1 Air inlet to pressure pot
2 Regulador de presión calderín
3 Discharge valve
YOU MUST ALWAYS CONNECT THE EQUIPMENT AND ALL THE ELEMENTS
INVOLVED IN THE WORK PROCESS TO A GROUNDING CONNECTION TO
ELIMINATE STATIC ELECTRICITY