Welding current
7
Allows the regulation of the welding current.
Minimum
3 A
Welding speed
399
Lets you set welding speed.
Default cm/min: reference speed for manual welding.
Syn: Sinergic value.
Minimum
1 cm/min
500
Allows the selection of the required graphic interface.
Allows access to the higher set-up levels.
Refer to section "Interface personalisation (Set up 500)"
Value
USER
SERV
vaBW
Lock/unlock
551
Allows the locking of the panel controls and the insertion of a protection code.
Refer to section "Lock/unlock (Set up 551)".
Buzzer tone
552
Permits adjustment of the buzzer tone.
Minimum
0/off
Regulation step
601
Allows the regulation of a parameter with a step that can be personalised by the operator.
Minimum
1
602
Circuit resistance calibration
705
Allows the calibration of the system.
Refer to section "Circuit resistance calibration (set up 705)".
Current reading
751
Allow the real value of the welding current to be displayed.
Voltage reading
752
Allows the real value of the welding voltage to be displayed.
Robot movement speed
758
Allows the arm movement speed of a robot or an automation device to be displayed.
Maximum
Default
Imax
100 A
Maximum
Default
200 cm/min
10 cm/min
Selected level
User
Service
vaBW
Maximum
Default
10
10
Maximum
Default
Imax
1
Value
User interface
XE
Easy Mode
XA
Advanced Mode
XP
Professional Mode