6. ACCESSORIES
Push-Pull kit
73.11.024
Consult the "Installation kit/accessories" section.
7. MAINTENANCE
Routine maintenance must be carried out on the system according to the manufacturer's instructions. When the
equipment is working, all the access and operating doors and covers must be closed and locked. The system must
not be modified in any way. Prevent conductive dust from accumulating near the louvers and over them.
Any maintenance operation must be performed by qualified personnel only. The repair or replacement of any parts
in the system by unauthorised personnel will invalidate the product warranty. The repair or replacement of any parts
in the system must be carried out only by qualified personnel.
Disconnect the power supply before every operation!
Parameter selection
Mode selection
Absolute value
4
Warning limits line
1
Alarm limits line
2
Minimum levels column
3
Maximum levels column
4
Select the required box by pressing the encoder key (the selected box is displayed
with reverse contrast).
Adjust the level of the selected limit by rotating the encoder.
Passing one of the warning limits causes a visual signal to appear on the
control panel.
Passing one of the alarm limits causes a visual signal to appear on the control
panel and the immediate blockage of the welding operations.
It is possible to set start and end of welding filters to prevent error signals
during the striking and extinction of the arc (consult the "Set up" section -
Parameters 802-803-804).
.