Mounting instructions for electricians:
Points 25 to 28:
Electrical connection:
Caution:
•
Electrical connections are reserved to
authorized electricans!
•
The safety regulations of the hairdressing trade must
be observed. Installation and operation must be in
accordance with the norm IEC 60364 ...
•
During assembly work the complete system must
be isolated from the power supply and secured
against unintended switch-on!
•
In the shampoo station, use only the plug-in
connectors supplied with the appliance and specified
in the mounting instructions!
•
Cables must be so arranged that they are not in the
vicinity or moving parts! Damage or crushing must
thus be prevented!
•
For reasons of mechanical security as well as the
electromagnetic compatibility no cable excess may
be stowed away in the shampoo unit.
•
In addition, there is a risk of overheating and even
a fire hazard if excess cable lengths are wound up.
•
No electrical installation that does not comply
with protection class IP66 may be laid within the
shampoo station! In particular, the use of
multiple socket strips can lead to a short circuit
and damage the shampoo station and pose a risk
to the user.
Shampoo station with direct connection:
•
The shampoo station must be connected to the
electrical floor outlet by a qualified electrician.
25. Remove the inspection cover on the back. To open,
press the chrome-plated button and pull to release
the magnetic connection (illustr. 2).
26. Make direct connection: (illustr. 9 – 12)
Disconnect the Wieland plug (H) from the Wieland
socket (K) (turn the ring on the plug from "lock
symbol closed" to "lock symbol open"). (illustr. 10)
Shorten the cable from the floor for as long as
possible little excess length within the shampoo
station.
Then remove the Wieland socket (K) from the mains
cable with plug and connect it to the cable from the
floor. (illustr. 11)
Plug the Wieland plug (H) of the shampoo station
connection cable into the Wieland socket (K) and
lock (illustr. 12).
27. Fasten the inspection cover on the back again
(magnetic lock). Push in the chrome-plated button
again (illustr. 2).
28. Switch on the power and carry out a function check
using the remote control.
Splendor Edition / Shiatsu MO B+R
GB
Mounting instructions for appliance fitters:
Shampoo station with mains cable:
•
•
•
•
29.
29. Arrange the power supply cable so that the plug is
30. If several shampoo stations are installed in a row, the
31.
31. Secure the cable routing above the floor using a plastic
32.
32. Fasten the inspection cover on the back again (magnetic
The shampoo station is „ready to plug in" and can be
plugged to a wall plug socket by the customer without the
help of an electrician.
The power supply cable from the unit must be
arranged so that it is not jammed between the unit
frame and the floor!
Always route the mains cable outside and plug into a
customer's site plug socket.
The shampoo station power supply cable must not be
connected to the power supply using an extension cable.
easily accessible and can be isolated from the wall
socket.
mains cable must not be routed through another system!
Cable routing over the floor!
cable duct (illustr. 3).
lock). Push in the chrome-plated button again (illustr. 2).
page 3 of 3