GENERAL WARNINGS
HYDRAULIC CONNECTION
Respect the order of the various hydraulic equipment (see page 17).
This product was designed to operate at air temperatures of between -5°C and
43°C inclusive, and water temperatures of above 4°C.
When winterising your pool, you must also shut down the Aéromax Piscine to
prevent any risk of failure during the winter, in particular frost-induced damage
to the exchanger.
ELECTRICAL CONNECTION
Be sure to turn off the power before removing the cover, to prevent any risk of
injury or electric shock.
The connection must comply with installation standard NFC 15-100, or the
recommendations in force in the country in which the Aéromax Piscine is to be
installed (see page 17).
Upstream of the appliance, the electrical installation must have an all-pole cut-
out device (circuit-breaker, fuse) compliant with the local installation rules in force
(30 mA residual current device).
If the power cable is damaged, it must be replaced by the manufacturer, the
latter's After-Sales service or a similarly qualified professional to prevent any
hazards. Earthing is mandatory. A special terminal marked
this purpose.
The ventilation hole must not be obstructed.
Service operations may only be performed on the refrigerant circuit by a skilled
and authorised refrigeration engineer.
The user manual for this appliance can be obtained from the After-Sales service.
These appliances comply with Directives 2014/30/EU on electromagnetic
compatibility, 2014/35/EU on low voltage, and 2011/65/EU on ROHS.
Environment: Do not dispose of your appliance with household waste;
take it to an official collection point for recycling.