2.5.
Electric Connection
Ensure that the electrical installation is designed to be able to connect the whole of the installation and is
compliant with the standards (NFC 15-100).
POWER
Electric Voltage
Rated Max Current (A)
Fuse Size
Circuit Breaker D curve
Cable Diameter
Data provided for information purposes for a heat pump power cable less than 20 m long. In case of
a longer cable, please refer to the standard.
Accessing the connection terminal block:
•
Unscrew the upper metal cover.
•
Unscrew the electrical compartment protective plate.
•
Electrically connect the product, feeding the cable through the gland.
Use the cable clamp to lock the cable in position.
5KW
7KW
230V/50Hz
230V/50Hz
7,4
7,6
10A
10A
10D
10D
2
3G2,5mm
3G2,5mm
9KW
230V/50Hz
7,9
16A
16D
2
2
3G2,5mm
17
12KW
14KW
230V/50Hz
230V/50Hz
14
15,9
20A
20A
20D
20D
2
3G4mm
3G4mm
2