Descargar Imprimir esta página

Modular EM70/40 FRE8+8 Instalación, Uso, Mantenimiento página 20

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

-
Defective gas tap or valve.
-
Temperature thermostat defective.
ELECTRIC FRYERS
THE APPLIANCE DOES NOT HEAT.
Possible causes:
-
Temperature thermostat defective.
-
Heating elements defective.
-
Safety thermostat tripped.
HEATING CANNOT BE ADJUSTED.
Possible causes:
-
Temperature thermostat defective.
18. REPLACING COMPONENTS
REMINDERS FOR REPLACING COMPONENTS
SHUT THE GAS SHUT-OFF VALVE
AND/OR SWITCH THE APPLIANCE
OFF
AT
INSTALLED UPSTREAM.
AFTER REPLACING A GAS SYSTEM
COMPONENT, CHECK FOR GAS
LEAKS AT CONNECTION POINTS.
DISCONNECT
ELECTRIC SUPPLY, IF PRESENT,
BEFORE
OPERATION.
AFTER REPLACING AN ELECTRICAL
SYSTEM COMPONENT, CHECK IT IS
CORRECTLY WIRED.
GAS FRYERS
REPLACING THE GAS VALVE AND SAFETY
THERMOSTAT.
-
Open the door.
-
Empty the well completely.
-
Remove the control panel.
-
Unscrew the locking nut on the exterior of the well.
-
Remove and replace the component.
THE
MAIN
SWITCH
THE
APPLIANCE
CARRYING
OUT
ANY
-
Change the sensor/bulb sealing O-Ring in the well.
-
Reassemble all parts. For assembly, proceed in
reverse order.
-
Slacken screw V.
-
Remove nozzle UM (fitted to air regulator Z) and
replace it with the one indicated in table TAB1.
-
Retighten nozzle UM(fitted to air regulator Z).
-
Adjust air regulator Z to distance A as shown in table
TAB1.
-
Retighten screw V fully.
-
Reassemble all parts. For assembly, proceed in
reverse order.
-
Open the door.
-
Remove the control panel.
-
Remove and replace the component.
-
Reassemble all parts. For assembly, proceed in
reverse order.
ELECTRIC FRYERS
REPLACING THE HEATING AND LIGHT GLOWS.
-
Remove the control panel.
-
Remove and replace the component.
REPLACING THE WORKING THERMOSTAT AND
SAFETY THERMOSTAT
-
Empty the well completely.
-
Open the door.
-
Remove the control panel.
-
Unscrew the locking nut on the heating element
flange.
-
Remove and replace the component.
-
Change the sensor/bulb sealing O-Ring in the well.
-
Reassemble all parts. For assembly, proceed in
reverse order.
19. CLEANING THE INTERIOR
Check the condition of the inside of the appliance.
Remove any built-up dirt.
Check and clean the fumes exhaust system.
20

Publicidad

loading