PACKING LIST
The EF117 unit pump is supplied complete with:
Bracket for wall installation
-
-
Prewired power cable, equipped with Schuko plug
Instruction manual
-
Note: The Kit-RX is available upon order, including Redox electrode with 2.5 m cable and BNC connector,
electrode holder with DN50 collar for direct in-line installation, and 220 mV calibration solution (90 ml).
INTRODUCTION
The EF117 digital unit is a redox meter, equipped with a double-pitch Schuko socket for powering a
dosing unit, as for example a salt chlorinator.
Depending on the measured value and set threshold, the unit supplies an output voltage for activating the
chlorinator.
The reading is continuously displayed; the "ON" LED is on with steady light during regular functioning, and
flashes quickly upon alarm or fault condition; the "PULSE" LED shows the output status and lights up
when the Schuko socket is powered.
The redox electrode input is available on BNC connector and the prewired power cable is provided with
Schuko plug, for an easy and fast installation.
TECHNICAL DATA
IN / OUT Power Supply
Electrical Protection
Display
RX Input
Measurement Range
Case
Installation
Protection Rate
Environment
Dimensions
Weight
EF117_r1.0 – 05/2018
230 V~, 50 Hz, single-phase; max 600 W
IN:
fuse F1A, 5x20 mm (F1 on the electronic board)
OUT: fuse F4A, 5x20 mm (in-line fuse-holder)
LED, 3 digits
on BNC connector, impedance > 10^12 Ohm,
Precision > 1% FS, repeatability > 0.2% FS
0 to +999 mV
PP reinforced with glass fibre
wall-mounting, with supplied bracket
IP54
Working Temperature
Storage Temperature
RH
100 x 160 x 135 mm
approx. 2 kg
max 45° C
max 60° C
max 90% no condensing