INSTALLATION
Install the device in a dry area, at a maximum ambient temperature of 45° C, and place it such as to al low
easy adjustment and maintenance operations.
Wall mount the unit using the supplied bracket. Secure the bracket to a vertical wall and hang the
instrument.
Electrical Connections
For the standard version the power cable is provided with Schuko plug. However, in special versions, the
three-wire power cable may be supplied without plug: phase (brown wire), neutral (blue) and earth
(yellow/green).
The mains circuit must be protected in accordance with the relevant laws and regulations. Typically, the
protection is given by a 30 mA differential switch and a breaker, or fuse of 5 A (or properly dimensioned
according to the load / salt chlorinator).
The input for redox electrode is available on BNC connector.
CONTROL PANEL
Display
During normal operations displays the redox (mV) measurement; the following
messages may also appear:
-
-
-
-
-
ON/OFF key
Enables/disables the system; press and hold for at least 3 seconds to enter the
CONFIGURATION mode
[-] key
Press and hold to display the electrode offset value (for 3 seconds) and then enter the
OFFSET CALIBRATION mode
[+] key
Press and hold to display the electrode gain value (for 3 seconds)
PULSE LED
Red light; flashes if the automatic mode is disabled (also see "Configuration" section)
ON LED
Green light; fixed ON indicates normal operations; flashes when an alarm occurs
EF117_r1.0 – 05/2018
OFF
the device has been disabled by pressing the ON/OFF button
PAU
the device is "Paused" at start-up (also see "Configuration" section)
ALL
an alarm is active (also see "Configuration" section)
UR
measurement out of range, below the minimum value (Under-Range)
OR
measurement out of range, above the maximum value (Over-Range)
p. 11