Descargar Imprimir esta página

Chauvin Arnoux F402 Guia De Inicio Rapido página 11

Multimetro a pinza
Ocultar thumbs Ver también para F402:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
E. THE SWITCH
(E1) OFF mode - Switches the clamp multimeter off
(E2) AC, DC, AC+DC
(E3) AC, DC
, AC+DC
(2) (3)
(E4) Continuity test
(E5) Temperature measurement
(E6) Power measurements (W, var, VA) and calculation of the power factor (PF)
(E7) Adapter function
(E8) Indicator of the order of the phases
F. THE TERMINALS
- Cold terminal (COM)
- Hot terminal (+)
G. VOLTAGE MEASUREMENT (V)
To measure a voltage, proceed as follows:
1.
Set the switch to
Connect the back lead to the COM terminal and the red lead to «+»,
2.
3.
Place the test probes or the crocodile clips on the terminals of the circuit to be
measured. The device selects AC or DC automatically according with to which
measured value is larger. The AC or DC symbol lights in blinking mode.
To select AC, DC or AC+DC manually, press yhe yellow key to reach the desired choice.
The symbol corresponding to the choice made then lights in fixed mode.
H. CURRENT MEASUREMENT (A)
For an AC current measurement, proceed as follows:
1.
Set the switch to
symbol is displayed,
2.
Encircle only the conductor concerned with the clamp.
The measured value is displayed on the screen.
(1) only F402
(2) only F404 - F604
(3) only F406 - F606
voltage measurement (V)
(3)
current measurement (A)
(3)
, Resistance measurement Ω, Diode test
(1) (2)
(2)
,
and select AC by pressing the
(3)
11
(3)
key. The AC

Publicidad

loading

Este manual también es adecuado para:

F404F406F604F606