Before use
To avoid damage, place the unit in an upright position for at least 24 hours before start-up. Make sure
that the air outlet and air inlet are never blocked.
Only operate the unit on a horizontal and perfectly level surface to ensure that no water escapes.
WARNINGS BEFORE USE
Do not exceed an impedance level greater than 0.236 ohms in the supply to which the appliance is
connected. Failure to comply may lead the supply authority to impose restrictions on the connection.
connection. Consult the power supply authorities if use of the equipment exceeds 0.236 ohms.
•
Any person involved in the handling or breakdown of a refrigerant in a refrigerant circuit must hold
a valid and up-to-date certificate issued by an industry-accredited assessment authority. This
authorises their competence to handle refrigerant safety in accordance with industry-recognised
assessment specifications.
•
Respect the environment when disposing of the device packaging and when the device has reached
its expiry date.
•
The device must be stored in a well-ventilated area whose size corresponds to the area of the room
specified for its use.
•
The device must be stored in such a way as to prevent mechanical damage.
•
Piping must be protected against physical damage; in the case of flammable refrigerants, the
installation of piping must be kept to a minimum; piping must not be installed in an unventilated
space.
•
Observe national gas regulations.
•
Mechanical connections must be accessible for maintenance;
•
For products containing flammable refrigerants, the minimum floor area of the room must be
mentioned in tabular or single-digit form without reference to a formula;
•
When the portable air is switched on, the fan can operate continuously and stably under normal
conditions to provide the minimum air volume of 100 m3 /h, even when the compressor is switched
off;
•
Pipes connected to the product must not contain any potential ignition source nearby;
•
Do not pierce or burn.
•
Use only materials recommended by the manufacturer for proper operation of the portable air.
•
Do not puncture any of the components of the refrigerant circuit. Refrigerant gas may be odourless.
•
Take care when storing the product to avoid mechanical failure.
•
All repairs should be carried out in accordance with the manufacturer's recommendations.
•
Maintenance and repairs requiring the assistance of other qualified personnel must be carried out
under the supervision of flammable refrigerant specialists.
PLEASE READ THE MANUAL CAREFULLY BEFORE USING THE PRODUCT.
R290 refrigerant gas complies with European environmental directives.
This product contains approximately 160 g of R290 refrigerant gas.
The product must be installed, operated and stored in a room with an area of
GAS R290
more than 7.7 m².
¡ADVERTENCIA!
25
English