Personal injuries and property damage from failure to observe the testing
criteria
Failure to observe the testing criteria can lead to personal injuries and property damage!
After installation and at regular intervals depending on the level of use (at least every
X
six months), ensure that the lifting point is still suitable for use. Also perform this
check after instances of damage and other relevant incidents.
Check more frequently if the product is subjected to critical operating conditions or
X
increased wear.
Testing criteria
Make certain that the bolt is screwed in firmly and with the correct tightening torque.
X
Ensure that the lifting point is complete.
X
Check that the load capacity information and the manufacturer's mark are complete and
X
legible.
Check the product for the following:
X
Deformation of load-bearing parts such as the main body and bolt
–
Mechanical damage, such as deep notches, especially in the areas under tensile load
–
Heavy corrosion
–
Cracks in load-bearing parts
–
Proper function and damage to the bolt or bolt thread.
–
Disposal
Dispose of the product safely and in an environmentally sound way.
X
Observe the national regulations, laws and rules.
X
EC declaration of conformity
In accordance with EC Machinery Directive 2006/42/EC, including its amendments,
manufacturer: Otto Ganter GmbH & Co. KG, Triberger Str. 3, 78120 Furtwangen
We hereby declare that the
by us, satisfies the applicable requirements of the EC Machinery Directive 2006/42/EC
and the fundamental safety and health requirements of the harmonized and national
norms as well as technical specifications listed below.
Applicable directive:
EC Machinery Directive 2006/42/EC
The following harmonized standards have been applied:
DIN 580:2018-04
–
DIN EN ISO 12100 : 2011-03
–
Person authorized to compile the conformity documentation:
Otto Ganter GmbH & Co. KG
Furtwangen, 03.05.2021
Stefan Ganter, Managing Director
WARNING
lifting eye nut DIN
Technical data see page 26
582, based on the design as marketed
7