2060-3060
eng.qxd
11/9/05
11:02
AM
Page
4
i
'\ b/
........
_i]i17 .......
OVERVIEW
OF POTENTIAL
HAZARDS
Overhead doors are large,heavy objects that move with the help of springs under high tension and electric motors. Since moving objects,springs under
tension, and electric motors can causeinjuries, your safety and the safetyof others depend on you reading the information in this manual. If you have
questions or do not understand the information presented, callThe GenieCompany. or your local Genie Distributor.
In this section, and those that follow, the words Danger, Warning
and Caution
are used to emphasize
important
safety
information.
The word:
.i_ DANGER:
indicates an imminently
hazardous situation
which, if not avoided, will result in death or serious injury.
WARNING:
indicates a potentially
hazardous
situation which, if not avoided, could result in death or serious injury.
-_ CAUTION:
indicates a potentially
hazardous
situation which, if not avoided, may result in injury or property
damage.
The word NOTE is used to indicate
important
steps to be followed
or important
considerations.
WARNING:
• Keep people clear of opening
while door is moving.
Could result in death
• Do Not allow children to play with the door operator.
or serious injury.
• Do Not operate a door that jams or one that has a broken spring.
MOVINGDOOR
ELECTRICAL
SHOCK
HIGHSPRING TENSION
WARNING:
Could result in death
or serious injury.
WARNING:
Could result in death
or serious injury.
• Turn off power before removing
operator
cover.
• When replacing cover, make sure wires are not pinched
or near
moving parts.
• Operator
must be properly
grounded.
• Do Not try to remove, repair or adjust springs or anything
to
which door spring parts are fastened, such as, wood blocks,
steel brackets, cables or other like items.
• Repairs and adjustments
must be made by a trained door
system technician
using proper tools and instructions.
WARNING:
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH:
1
READ AND FOLLOW ALL SAFETY, I NSTALLATIONAND
OPERATIONINSTRUCTIONS. I f you have any
questions or do not understand an instruction, call
your authorized Genie installation professional.
2
Do Not install operator on an improperly balanced
door. An improperly balanced door could cause
severe injury. Repaffs and adjustments to cables,
spring assembly, and other hardware must be made
by a trained service person using proper tools and
instructions.
3
Remove all ropes, and disable all locks connected to
the door before installing operator.
4
Install door operator 7 feet or more above the floor.
Mount the emergency release knob 6 feet above
the floor.
5
Do Not connect the operator to the source of power
until instructed to do so.
6
Locate the control button:
Within sight of door.
At a minimum height of 5 feet, so small children
cannot reach it.
• Away from all moving parts of the door.
7
Install the entrapment WARNING label next to the
wall button or console. Install the emergency release
tag on, or next to, the emergency release
8
The operator must reverse when the door contacts a
1-1/2 inch high object on the floor at the center of
the doorway.This is about the size ofa 2"x 4" board
laid flat.
Safe-T-Beam ® (STB) Non-Contact Reversing System
Places an invisible beam across door opening, that reverses
the door during down travel to the fully open position if
anything passes through beam.
Safe-T-Reverse ® Contact Reversing System
Automatically
stops and reverses a closing door within 2
seconds of contact with an object.
Safe-T-Stop ® Timed Reversed System
Automatically
opens a closing door, if door does not close
within 30 seconds.
ForceGuard ® Control
Used to set the force required for opening and closing
door. For maximum safety, set the minimum force required
to fully open and close door.
Automatic Lighting System
Light bulbs up to 60 Watts max., used for safer entries and
exits.The lights turn on when door is activated and
automatically turn off 4.5 minutes later.
Manual Emergency Release
Allows the garage door to be opened or closed manually
for emergencies or maintenance.
4
I
<_I" Js_<, %%%1,<÷Is_,
01]11-I<_ iiy 1(oI]l
........
\X7 ...
i
.........................
_:i ........................