Save Memory: Store the welding programs
with their parameters to one of the fifty user
Memories.
To save memory:
Add Save Memory icon to Welding Parameters Bar.
Use the Right Knob [36] to highlight the icon Save
Memory.
Figure 20.
Press the Right Knob [36] to confirm – the Save
Memory Menu is shown on the display .
Use the Right Knob to highlight the memory number
where the program would be stored.
Figure 21.
Confirm the selection – Press and hold for 3 second
Right Knob [36].
Figure 22.
Rename job – turn Right Knob [36] to select:
numbers 0-9, letters A-Z, a-z. Press Right Knob [36]
to confirm first character of the name.
Next characters are selected in the same.
To confirm the name of job and back to the main
menu press Button [37] or Left Knob [35].
English
Load memory
Recall the stored programs from the user Memory.
To recall the Welding Program from
the User Memory:
Note: Before using, the Welding Program had to be
assigned to the user memory
Add the Load memory icon to the Welding
Parameters Bar.
Use the Right Knob [36] to highlight the Load
memory icon.
Press the Right Knob [36] to confirm – the Load
Memory Menu is shown on the display.
Use the Right Knob [36] to highlight the Memory
number which from the Welding Program will be
recall.
Confirm the select – press the Right Button [36].
USB
When the USB storage device is connected
to USB port – user have access to:
Table 10. USB Menu
Symbol
Description
Save
Load
Save - the following data can be save on a USB Memory
Stick:
Table 11. Save and restore selection
Symbol
Current Welding Settings
Advanced Parameters Configuration
(P menu)
All welding programs stored in user
memory
One of the welding programs stored in
M1
user memory
M50
21