Terminals
Input/Output
PHOTOCELLS
15 - 16
(N.C. contact)
PRESENCE DETECTORS
17 - 18
TEST
CONNECTOR J16:
Terminals
Input/Output
EMERGENCY
(N.C.)
19 - 21
(21= Common)
CLOSE/LATCHING
RELAY
20 - 21
(N.O.)
DIP # 7 on SW1 on OFF
(21= Common)
CLOSE/LATCHING
RELAY
20 - 21
(N.O.)
DIP # 7 on SW1 on
ON(21= Common)
INTERLOCK
21 - 22
(N.C.)
(21= Common)
SIDE SENSOR
23 - 21
(N.C.)
(21= Common)
STOP/
ANTI-PANIC
24 - 21
(N.C.)
(21= Common)
NOTE: The STOP lock/function blocks any movement in progress of the automation, while
Door Status Function
Closed
None.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won't close until photocells are released.
In pause
None.
17= + TEST
18= - TEST
Door Status Function
Opens in any program, except in "LOCKED". When
Closed
dip # 1 on SW1 is set on ON opens also in "LOCKED".
Opening
None.
Closing
Reverts motion and opens.
Open
Door won't close until input is released.
In pause
None.
Closed
None.
Opening
Reverts motion and opens.
Closing
None.
Open
Closes in any program, except in "HOLD OPEN".
In pause
None.
Closed
Opens in any program, except in "LOCK".
Opening
Reverts motion and closes, except in "HOLD OPEN".
Closing
Reverts motion and opens, except in "LOCK".
Closes in any program, except in "HOLD OPEN".
Open
IMPORTANT: Auto Close function is disabled.
In pause
Closes.
Prevents the opening of the other door when the
Closed
Interlock is operating
Opening
None.
Closing
None.
Open
None.
In pause
None.
Closed
None.
Opening
Opening continues at reduced speed.
Closing
None.
Open
None.
In pause
None.
Closed
The door does not open so long as the input is busy.
Opening
It stops the automation.
Closing
It stops the automation.
Open
The door does not close so long as the input is busy.
The door does not open so long as the input is
In pause
busy. Once free, the door closes at reduced speed
after 5 seconds.
21