LOGIC ADJUSTMENTS
Trimmer
TM1
TM2
TM3
TM4
TM5
TM6
TM7
Dip switch SW1
1
EMERGENCY
2
ELECTRO-LOCK
3
BATTERY MONITORING
4
OPENING IN BATTERY
TCA
5
INCREASE
6
FUNCTION
7
ENTRANCE
CH/PP
FUNCTION
8
ENTRANCE
STOP/ ANTI-PANIC
9
INTERLOCK FUNCTION
Function
OPENING
SPEED
CLOSING
SPEED
OPENING
TORQUE
CLOSING
TORQUE
OPENING
SOFT STOP
CLOSING
SOFT STOP
AUTO CLOSE
DELAY
ON
Enables opening with always closed program.
OFF
Disables opening with always closed program.
Enables the electric lock when the automation is closed, regardless
ON
of the selected program.
Enables the electric lock when the automation is closed only with
OFF
the "always closed" program.
If there is no voltage, the automation performs the manoeuvres
ON
normally. If the battery is flat, the board switches off.
If there is no voltage, the automation performs the manoeuvres
OFF
normally. Before the battery is fully discharged, it performs an
opening manoeuvre.
In the event of a power failure, the automation opens and remains
ON
open until the mains voltage is restored (DIP3 must be OFF)
In the event of a power failure, the automation performs the ma-
OFF
neuvers normally.
With a high flow of passages, the automatic closing time is auto-
ON
matically increased.
OFF
Function disabled, the automatic closing time remains unchanged.
ON
OFF
Keep the Dip switch in OFF
ON
Enables the Step-by-Step function.
OFF
Enables the CLOSING function on input 20.
ON
Enables the STOP function on STOP/ANTI-PANIC input.
OFF
Enables the ANTI-PANIC function on STOP/ANTI-PANIC input.
ON
Enables INTERLOCK function
OFF Disables INTERLOCK function
Description
Adjusts Opening Speed.
Adjusts Closing Speed.
Adjusts Opening Torque.
Adjusts Closing Torque.
Sets the opening slowdown duration
Sets the closing slowdown duration
Adjusts Auto Close Delay.
25