TESTING
Once the connection is completed:
The green LEDs (DL7-8-9-11-12-13) must all be lit (they correspond to a Normally Closed input
each). They switch off only when the controls they are associated to are involved.
The red LEDs (DL5-6-10) must all be off (they correspond to a Normally Open input each); they
light only when the controls they are associated to are involved.
TECHNICAL CHARACTERISTICS
Board power supply
Max motor power DC
Fast acting fuse entrance 230V AC (F5 - 5x20)
Fast acting fuse for protection of auxiliary circuits 24 V CC (F1 -
5x20)
Fast acting fuse for motor protection 40Vcc (F2 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
WORKING PROGRAMS
Six different working programs can be selected (can be set by mechanical selector or by TLINETD
programmer):
"SOLO ENTRATA" (ENTRY ONLY)
"SOLO USCITA" (EXIT ONLY)
"ENTRAMBI I SENSI" (AUTO)
"SEMPRE APERTA" (HOLD OPEN)
"BLOCCATA CHIUSA" (LOCK)
"APERTURA INVERNALE" (WINTER OPENING)
"APERTURA FARMACIA" (PHARMACY OPENING) (only through the TLINETD device)
Program
"SOLO ENTRATA"
(ENTRY ONLY)
"SOLO USCITA"
(EXIT ONLY)
"ENTRAMBI I SENSI"
(AUTO)
"SEMPRE APERTA"
(HOLD OPEN)
"BLOCCATA CHIUSA"
(LOCK)
Description
Entering Traffic
Exiting Traffic
Two-Way Traffic
Door remains always open
Door remains always closed Emergency
Active inputs
Outside Radar
Close (Latching Relay)
Emergency
Inside Radar
Close (Latching Relay)
Emergency
Outside Radar
Inside Radar
Close (Latching Relay)
Emergency
19
230 V AC - 50 Hz
100 W - 40 V DC
3.15A
2 A
6,3 A
40 V DC
24 V DC
5 V DC
-20 °C ÷ +55 °C
Remarks
Emergency Input
works only when dip
# 1 on SW1 is set on
ON