5 MANAGEMENT
5.1. STORAGE
All the pumps must be stored indoors. in a dry. vibration-free and dust-free environment, possibly
at constant air humidity.
They are supplied in their original packaging and must be kept there until installation.
5.2. TRANSPORT
Avoid subjecting the products to needless jolts or collisions.
The electropumps must never be carried or lifted by their power cables.
6 WARNINGS
6.1. QUALIFIED PERSONNEL
Installation should be performed by skilled and qualified personnel, in possession of
the technical qualifications required by the specific regulations in force.
The term qualified personnel means persons who, because of their training, experience and
regulations as well as all operating circumstances, have been entitled by the person
responsible for the system to work on and with the system and to see and avoid all possible
dangers (Definition for technical personnel IEC 364).
The appliance is not intendend for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsable for
their safety. Children should be supervised to ensure that they do not play with the appliance.
6.2. SAFETY
Use is allowed only if the electric system is provided with safety precautions in accordance with
the regulations in force in the country where the product is installed (for Italy, CEI 64/2).
Never let the pump run dry.
The pump cannot be used in swimmingpools, ponds or tanks in which people are present.
The pump is provided with a handle to which a rope or cable may be connected to lower the
machine into working position.
The pumps must never be carried, lifted or operated hanging from their power cables.
Qualified personnel must be employed for all electrical repairs which, if badly carried out, could
cause damage and accidents.
6.3. MOTOR SHAFT ROTATION CHECK
If the motor does not work and the shaft does not turn when the switch and/or float is operated, you
must check that all working parts are turning freely.
To do this:
- Completely disconnect the pump from the mains.
- Place the pump in a horizontal position.
- Remove the grill and the diffuser, and operating on the self-loccking-nut with a fork wrench 13,
rotate the shaft motor clockwise.
- Reassemble the grill and the conveyor and install the electropump as indicated in chapter 7.
6.4. RESPONSIBILITY
The Manufacturer does not vouch for the correct operation of the pumps and will not be
responsible for damages that might be caused by them, in case they are tampered with
or modified, run outside the recommended work range or in contrast with the other
instructions given in this manual.
The Manufacturer assumes no liability resulting from or omissions in this booklet, if
due to misprints or errors in copying. The company reserves the right to make
modifications to the products described herein, when considered necessary or useful,
without changing the essential characteristics of the product itsef.