Descargar Imprimir esta página

Craftsman 919.167312 Manual De Instrucciones página 19

Ocultar thumbs Ver también para 919.167312:

Publicidad

Idiomas disponibles

Idiomas disponibles

To Replace
Regulator
1=
Release alI air pressure from air
tank, See "To Drain Tank" in the
"Maintenance"
section=
2.
Set the On/Auto/Off
lever to "Off"
and unplug unit.
3.
Remove the outlet pressure
gauge and quick connect (if
equipped) from the regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple.
6.
Assemble the regulator and
orient as shown.
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
Regulator
7=
8=
Reapply pipe sealant to outlet
pressure gauge and quick
connect.
Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten quick connect
with wrench.
19= ENG
A09707

Publicidad

loading