Descargar Imprimir esta página

Gaggenau CV282101 Instrucciones De Montaje página 19

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
Remove the adhesive tape's protective film from
3.
the adapter.
→ Fig.
32
Inserting the appliance into the worktop cut-out
Ensure that the connection cable is connected to
1.
the appliance.
Carefully insert the appliance into the worktop cut-
2.
out.
→ Fig.
33
Aligning the appliance in the worktop cut-out
Use the enclosed spacers to adjust the circumfer-
1.
ential gap between the appliance and the worktop
to a uniform distance of 1.5 to 2 mm.
→ Fig.
34
Remove the spacers before sealing the join.
2.
Screwing the retaining clips in place
Screw the enclosed retaining clips onto the work-
top and carefully onto the appliance.
Ensure that the hob is at the same height as the
worktop and the appliance does not slip.
Do not use an electric screwdriver.
→ Fig.
35
Securing the adapter
Hold the adapter at the central holder and use the
1.
side holders to slide it towards the unit's back
panel in the base unit, then affix it.
→ Fig.
36
If required, also use screws to secure it.
2.
→ Fig.
37
Installing the appliance for air recirculation mode
with circulating-air duct
For circulating-air mode, use the seal, the circulat-
1.
ing-air duct, the diffuser and the odour filter.
Observe the dimensions for the different flat duct
2.
bends. → Page 15
Securing the seal
Secure the enclosed seal on the flat duct elbow at
a maximum of 5 mm from the edge.
→ Fig.
38
Inserting the flat duct elbow
Insert the flat duct elbow into the outlet opening
on the rear of the appliance.
→ Fig.
39
Inserting the appliance into the worktop cut-out
Ensure that the connection cable is connected to
1.
the appliance.
Carefully insert the appliance into the worktop cut-
2.
out.
→ Fig.
40
Aligning the appliance in the worktop cut-out
Use the enclosed spacers to adjust the circumfer-
1.
ential gap between the appliance and the worktop
to a uniform distance of 1.5 to 2 mm.
→ Fig.
34
Remove the spacers before sealing the join.
2.
Establishing the pipework between the appliance and
the diffuser
Connect the components of the circulating-air duct
1.
to each other.
Secure the flat duct pipe connector by enga-
ging it in place.
For an additional fixing, screw the flat duct pipe
connector together using 4 x PT 4x8 mm
screws for plastic.
→ Fig.
41
Connect the circulating-air duct to the flat duct el-
2.
bow on the rear of the hob.
→ Fig.
42
Connect the diffuser to the circulating-air duct.
3.
→ Fig.
43
Screwing the retaining clips in place
Screw the enclosed retaining clips onto the work-
top and carefully onto the appliance.
Ensure that the hob is at the same height as the
worktop and the appliance does not slip.
Do not use an electric screwdriver.
→ Fig.
35
Install the appliance for air extraction mode
For air extraction mode, use the seal and the
1.
acoustics filters.
Observe the instructions for the exhaust air pipe.
2.
→ Page 17
Securing the seal
Secure the enclosed seal on the flat duct elbow at
a maximum of 5 mm from the edge.
→ Fig.
38
Establishing the piping
Insert the flat duct elbow into the outlet opening
1.
on the rear of the appliance.
→ Fig.
39
If required, install additional piping elements.
2.
Inserting the appliance into the worktop cut-out
Ensure that the connection cable is connected to
1.
the appliance.
Carefully insert the appliance into the worktop cut-
2.
out.
→ Fig.
40
Screwing the retaining clips in place
Screw the enclosed retaining clips onto the work-
top and carefully onto the appliance.
Ensure that the hob is at the same height as the
worktop and the appliance does not slip.
Do not use an electric screwdriver.
→ Fig.
35
Connecting the exhaust air pipe
Secure the exhaust air pipe to the flat duct bend.
1.
Establish the connection to the exhaust air open-
2.
ing.
Seal the joints appropriately.
3.
Aligning the appliance in the worktop cut-out
Use the enclosed spacers to adjust the circumfer-
1.
ential gap between the appliance and the worktop
to a uniform distance of 1.5 to 2 mm.
→ Fig.
34
Remove the spacers before sealing the join.
2.
Inserting filters
Note: For circulating-air mode, insert the odour fil-
ters.
For air extraction mode, insert the acoustics filters.
Observe the filters' air flow direction.
1.
Insert two of the filters into the left and right of the
2.
appliance, and slide them forwards.
→ Fig.
44
Insert the other filters into the left and right of the
3.
appliance.
→ Fig.
45
Inserting grease filters
Insert the grease filter.
→ Fig.
46
Positioning the ventilation grille
Position the ventilation grille.
→ Fig.
47