7.2.5. Diagnostic parameters
Parameter Name
Operating Hours
Number of Power Cycles
Maximum temperature
– All time high
Minimum temperature
- All time low
Maximum temperature since
power-up
Minimum temperature since
power-up
Current temperature
Detection counter SSC1
Minutes above Maximum
Temperature
Minutes below Minimum
Temperature
Maintenance event counter
Download counter
32
Rev.00 - 10.2023 | CA12CA/EA/KA Capacitve sensors with IO-Link interface | © 2023 | CARLO GAVAZZI Industri
Index Dec
Access
(Hex)
201 (0xC9)
RO
202 (0xCA)
RO
203 (0xCB)
RO
204 (0xCC)
RO
205 (0xCD)
RO
206 (0xCE)
RO
207 (0xCF)
RO
210 (0xD2)
RO
211 (0xD3)
RO
212 (0xD4)
RO
213 (0xD5)
RO
214 (0xD6)
RO
Default value
0
0 ... 2 147 483 647 [h]
0
0 ... 2 147 483 647
0
0
-
-
-
-
0 ... 2 147 483 647
-
0 ... 2 147 483 647 [min]
-
0 ... 2 147 483 647 [min]
0
0 ... 2 147 483 647
0
Data range
Data Type
IntegerT
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
-50 to 150 [°C]
IntegerT
IntegerT
IntegerT
IntegerT
IntegerT
0 ... 65 536
UIntegerT
Length
32 bit
32 bit
16 bit
16 bit
16 bit
16 bit
16 bit
32 bit
32 bit
32 bit
32 bit
16 bit