(6) RET/EXIT/SPOT SET
① RET
Returning to the main menu.
② EXIT
To save setup parameters and to quit.
③ SPOT SET
Displaying the screen of Spot area
setting, shown on the right.
1) ↑ : For the upper area control,
use this arrow and push E
button.
By using U or D button,
decide the area and return to
the light control mode by E
button.
2) ↓ : To move the lower area setting mode by choosing this arrow and
push E button. By U or D button, decide the area and return to the
light control mode by E button.
3) ← : To select this for left side area setting mode. Using L or R button,
decide the area, then return to the light control mode by E button.
4) → : This arrow is for the control of the right side area. By L or R button,
decide the area, then return to the light control mode by E button.
5-4-5. GAIN
(1) By L or R button, the gain control modes can be selected.
① LOW
This fixed-gain mode keeps the sensitivity low for brighter spots.
This can be used for relatively comfortable picture reproduction with less
video noise. Normally it is used with ample light condition.
② MID
This fixed-gain mode keeps the sensitivity middle between HIGH and LOW.
③ HIGH
The fixed-gain mode keeps the sensitivity high for darker scene.
④ AGC
This mode is initially set to automatically optimize the sensitivity and noise
levels.
           ↑