16. INSTALL THE DECORATIVE FLUE
1. To prevent the flue from moving, affix the included foam squares on both sides near
the front edge of the blower box (as illustrated at right).
2. Carefully slide in place decorative lower flue (notches end first) on top of the hood (1)
until flue notches completely fit in hood slots (2).
Slide up the upper flue until it is aligned with its mounting bracket. The bracket must be
inside the flue. Secure the upper flue to its bracket using 2 no. 8 x 3/8" screws for stainless
steel model or 2 no. 8 x 1/2" quadrex black screws for black stainless steel model (included).
See illustration beside.
NOTE: Duct not shown in illustration to ease understanding.
Remove protective plastic film covering the upper flue.
17. REINSTALL HYBRID FILTERS
Remove protective plastic film covering filters before reinstalling them.
Rest rear filters edge on filter springs in the range hood. Tilt up the filters into position.
Make sure filter tabs are securely engaged in range hood front edge slots after installation.
CAUTION
11
HO0192
1
2
HO0187
U
PPER FLUE MOUNTING BRACKET
F
RONT VIEW
U
PPER
FLUE
HO0140
F
ILTER TABS
HO0351