OPERATING INSTRUCTIONS
en
6.4
Configuration
52
O P E R A T I N G I N S T R U C T I O N S | WTM4S
Minimum object height in mm (inch)
y
7
(0.28)
6
(0.24)
5
(0.20)
4
(0.16)
3
(0.12)
90%/90%
2
(0.08)
1
(0.04)
0
0
50
100
150
(1.97)
(3.94)
(5.91)
Recommended sensing range for
the best performance
Figure 11: WTM4S-xxxxx8xx, MultiMode 2
1
0/10
160
2
0/10
0
50
100
150
200
(1.97)
(3.94)
(5.91)
(7.87)
Distance in mm (inch)
D
C
A
Recommended sensing range for
the best performance
Figure 12: WTM4S-xxxxx8xx, MultiMode 2
Black background, 6% remission factor
1
White background, 90% remission factor
2
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Visibility range
D
Adjustable switching threshold for foreground suppression
E
Sensing range indicator
F
Teach-Turn adjustment
Blue
Recommended sensing range for the best performance
MultiMode
The WTM4S sensor is set in 3 steps:
Example:
Reliable detection of the object
6%/6%
90%/6%
1
6%/90%
2
x
Black background (6 % remission factor)
200
250
300
Distance of sensor to background x = 100 mm
(7.87)
(9.84)
(11.81)
Required minimum object height y = 1.9 mm
Distance in mm (inch)
For all objects regardless of their colors
250
250
300
(9.84)
(11.81)
BluePilot
E
F
B
x
y
Background
8028212/2023/10/20 | SICK
Subject to change without notice