Electrical / Motor Specs
(3 - Stage)
MAX OIL FLOW
Stage 1 (1000psi / 70bar)
Stage 2 (3900psi / 270bar)
Stage 3 (10,000psi / 700bar)
WARNING
Loose or improperly threaded fittings can be potentially dangerous if pressurized; however,
severe over tightening can cause premature thread failure. Fittings need to be tightened
secure and leak free. Never hold or stand directly in line with any hydraulic connections
while pressurizing. Never grab, touch or in any way come in contact with a hydraulic
pressure leak. Escaping oil can penetrate the skin and a serious injury can result.
CAUTION
Do not subject the hose to potential hazards such as sharp surfaces, extreme heat or
heavy impact. Do not allow the hose to kink or twist. Inspect each hose for wear before it is
used.
ELECTRICAL
Check for proper electrical supply before connecting. Be sure the electrical connection is
grounded. Check that your power supply agrees with the motor nameplate and/or manufacturer
model decal.
NOTE: MOTOR MAY SPARK. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE OR IN
THE PRESENCE OF CONDUCTIVE LIQUIDS.
1. Do not use a power or extension cord that is damaged or has exposed wires.
2. All single phase motors come equipped with a three prong grounding type plug to fit the
proper grounded type electrical outlet. Do not use a two prong ungrounded extension cord
as the pump's motor must be grounded.
CONNECTING HYDRAULIC TOOLS
Use only tools, hoses and accessories rated at 10,000 PSI (700kg/cm2). When making
connections with quick disconnect couplings, make sure the couplings are fully engaged.
Threaded connections such as fittings, gauges, etc. must be securely tightened and leak
free. Use 1.5 wraps of Teflon tape (or suitable thread sealant) on all threads, leaving the first
complete thread free of tape to ensure no foreign matter enters the hydraulic circuit.
STARTING THE PUMP FOR THE FIRST TIME
SERVICE SUPPLY
115V: 1Ph 100 125 / 50+60Hz
230V: 1Ph 200 230 / 50+60Hz
115V: 1.6 kW / 2.2 HP 15 Ampere
230V : 1. 6 kW / 2.2 HP 8 Ampere
Max. Current draw
100bar (idle)
500bar
700bar
50Hz
490 cu.in/min
8.0 l/min.
120 cu.in/min
2.0 l/min.
55 cu.in/min
0.9 l/min.
MOTOR DRAW
115V
13.3A
15.5A
17.8A
610 cu.in/min
145cu.in/min
65 cu.in/min
230V
8.3A
8.8A
9.3A
60Hz
10.0 l/min.
2.4 l/min.
1.1 l/min.