PRESSURE TORQUE SETTING
WARNING
Make these adjustments BEFORE putting torque wrench on nut or bolt head. The pump
pressure setting may be above the pressure needed to provide the required torque for
your application.
Exceeding required torque will cause equipment damage and may lead to serious
personal injury.
1. See torque wrench instructions for amount of pressure required to produce desired torque.
2. Loosen lock nut and back out relief valve to prevent unintended pressure builds up.
3. Turn pump on. Press and hold the "ADV" switch, and read pressure gauge.
4. While holding the switch, turn relief valve in (clockwise) to increase pressure or out (counter-
clockwise) to decrease maximum pressure. Repeat until correct pressure is obtained.
5. Tighten lock nut on the relief valve to maintain setting.
6. Run pump several times to test this setting before setting tool on the nut.
AFTER COMPLETING THE JOB
Before disconnecting hoses, fittings, etc., first be sure the tool is unloaded and retracted, then
unplug the power cord.
Press "ADV" to
turn pump ON
Press and release
"ADV" to cycle
OPERATION PROCEDURES
Adjusting Knob
Lock Nut
Valve Assembly
Press "OFF" to
turn pump OFF
33