HCS-D User Manual
HCS-D EVSE Mounting for Hollow-Wall Construction
Place the unit such that both mounting holes can take
advantage of solid structural framing inside of the wall or a
strong wall surface such as plywood.
Size ¼"- 20 lag screws are recommended for mounting the
HCS-D to a wooden structure. Pre-drill appropriately sized
pilot holes to allow the lag screw to grip the wooden structure
while preventing the wood from cracking or splintering while
the screw is fastened.
The included plastic angle washers can be oriented to allow
the lag screws to be fastened at an angle while still providing a
solid flat backing to the screw head.
If the screw head is smaller than the 3/8" washer aperture,
an additional flat washer will need to be placed between the
plastic angle washer and the head of the lag screw.
If either mounting hole does not have a solid mounting
structure (such as drywall without a solid backing) it will be
necessary to use proper anchoring hardware such as drywall
toggles or molly bolts.
Figure 5: Mounting the HCS-D to a Hollow-Wall
17
"
Note Diagonal Mount
Washer is marked with
an "O" shape
Diagonal
Perpendicular
Screw Mount
Screw Mount
Shorter
18
Longer